GENERAL INFORMATION
|
 |
Model Type |
ULTIMATE LCD RM |
 |
Model Name |
ULT-3000RM LCD |
 |
Power Rating |
3000VA |
 |
 |
AC INPUT
|
 |
AC Input Voltage |
100V:76V~130V 110V:80V~138V 115V:83.5V~140V 120V:87V~140V 208V:152V~260V 220V:160V~276V 230V:167V~280V 240V:174V~280V |
 |
AC Input Frequency |
50 or 60 Hz+/-3 Hz |
 |
AC Input Phase |
Single |
 |
AC Input Power factor |
>= 0.98 |
 |
 |
AC OUTPUT
|
 |
AC Output Voltage |
100V/110V/115V/120V or 208V/220V/230V/240V |
 |
AC Output Frequency |
50Hz/60Hz (Auto detection) |
 |
AC Output Frequency Stability |
(+/-0.5%) |
 |
AC Output Voltage Regulation |
(+/-2%) |
 |
AC Output Powerfactor |
0.7 (lagging) |
 |
AC Output Hamonic distortion |
<3% of T.H.D. at linear load |
 |
AC Output Overload detection |
105% for 10 seconds and 130% +/- 10% for 300ms |
 |
AC Output Crest factor ratio |
( 3:1 ) |
 |
 |
 |
TRANSFER
|
 |
Transfer Power failure Recovery |
0 ms |
 |
Transfer Overload Disappear |
Auto transfer to UPS |
 |
Transfer UPS to By Pass or Vice Versa |
0 ms |
 |
 |
NOISE
|
 |
Noise Level 1m Distance |
< 52dBA |
 |
 |
PROTECTION
|
 |
Protection Spike |
150 Joules |
 |
 |
BATTERY
|
 |
Battery Type |
Sealed lead acid battery, free-maintenance |
 |
Battery Protection |
Cut off without draining any current when battery low |
 |
Battery DC Voltage |
96V |
 |
 |
BACKUP TIME
|
 |
Battery Backup Time Full Load |
7 minutes |
 |
Battery Backup Time Half Load |
20 minutes |
 |
Battery Recharge Time |
About 8 hours to 90% after fully discharged |
 |
 |
PHYSICAL
|
 |
Physical Weight kgs RM |
32 |
 |
Physical Weight lbs RM |
70.4 |
 |
Physical Dimension mm RM |
430x480x130 |
 |
Physical Dimension inch RM |
16.9x15.7x5.1 |
 |
 |
INDICATOR
|
 |
LCD |
LCD |
 |
LCD Indicators Status |
Indicate line, bypass, inv, backup, fault, bat capacity, load capacity, I/P frequency, O/P voltage, O/P frequency, inside temperature, fault status |
 |
 |
ALARM
|
 |
Alarm Battery Discharge |
The first warning will beep every 4 seconds to indicate battery in use. The second warning will beep every 1 second to signal battery low condition |
 |
Alarm UPS Fault |
Continuous beeping sound |
 |
 |
INTERFACE
|
 |
Interface Dry Contact |
Sends AC fail and battery low signals, and receives shutdown signal from computer |
 |
Interface RS-232 |
Detect battery low, Schedule UPS on/off, AC input/output power status display |
 |
Interface Option |
Novell, SNMP, Windows NT, Window 95/98/2000/ME/XP |
 |
 |
ENVIRONMENT
|
 |
Environment Temperature |
0 deg C ~ 40 deg C |
 |
Environment Humidity |
0%~95% (Non condensing) |
 |
ShowOrder |
107 |
 |
 |