KOF-750S
GENERAL INFORMATION
Model Type KING OFFICE
Model Name KOF-750S
AC INPUT
AC Input Capacity on Battery 100V: 85+/- 3V~115 +/- 3V, 115V: 94+/- 3V ~ 136 +/- 3V, 220V: 180 +/- 6V ~ 260 +/-6V, 240V: 204 +/- 7V ~ 276 +/- 7V
AC Input Frequency 50 or 60 Hz+/-5Hz(auto sensing)
AC Input Transfer N/A
AC OUTPUT
AC Output Voltage Simulated sine wave at 110V / 115V or 220V / 230V +/-5%
AC Output Frequency 50 or 60 Hz +/- 0.5%
AC Output Voltage Regulation 0
AC Output Transfer 2 ~ 4 milliseconds typically, including detection time
PROTECTION
Protection Spike 240 Joules, 2ms
Protection EMI/RFI 10dB at 0.15 MHz, 50 dB at 30 MHz
Protection Overload N/A
Protection Unit N/A
Protection 10 BaseT N/A
Protection Short Protection N/A
BATTERY
Battery Type User Replaceable, sealed, Maintenance-free lead acid
Battery Typical 4 hours
Battery Protection Automatic self-test & discharge protection, replace battery indicator
BACKUP TIME
Battery Backup Time Full Load 16 minutes
Battery Backup Time Half Load 33 minutes
PHYSICAL
Physical Weight kgs Tower 4.2
Physical Weight lbs Tower 9.2
Physical Shipping Weight kgs 4.5
Physical Shipping Weight lbs 9.9
Physical Dimension mm Tower 420x170x65
Physical Dimension inch Tower 16.5x6.7x2.6
Physical Input Inlet IEC 320 inlet
Physical Receptacles NEMA 5-15R (115V) / IEC 320 female appliance coupler (230V)
INDICATOR
LED LED
MAINTENANCE
ALARM
Alarm Battery Backup Slow beeping sound (about 0.47 Hz)
Alarm Battery Low Rapid beeping sound (about 1.824Hz)
Alarm Overload N/A
INTERFACE
Interface RS-232 Bi-directional communication port
ENVIRONMENT
Environment Ambient 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg c
Environment Audible <50dBA (1 meter from surface)
ShowOrder 3