HOM-400A
GENERAL INFORMATION
Model Type HOME
Model Name HOM-400A
AC INPUT
AC Input Capacity on Battery 400VA
AC Input Voltage (+/-) 25% at line input
AC Input Frequency 50 or 60 Hz+/-10% (auto sensing)
AC OUTPUT
AC Output Voltage Simulated sine wave at 100V/115V or 230V +/- 5%
AC Output Frequency 50 or 60 Hz +/- 1Hz
AC Output Voltage Regulation AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 15% below input voltage if +9% to +25% of nominal
PROTECTION
Protection Spike 80 Joules / 2ms
Protection Unit Input Fuse or circuit breaker for overload & short circuit protection
Protection Overload Protection UPS automatic shutdown if overload exceeds 110% nominal at 60 sec and 130% at 3 sec
Protection Short Circuit UPS output cut off immediately (firmware) or input fuse, circuit breaker protection
BATTERY
Battery Type Sealed, Maintenance-free lead acid
Battery Protection Automatic self-test & discharge protection, replace battery indicator
Battery DC Voltage 12V (DC)
BACKUP TIME
Battery Backup Time Full Load 29 minutes
Battery Backup Time Half Load 60 minutes
Battery Recharge Time 6 hours typically (to 90% full capacity)
Battery Quantity 3
PHYSICAL
Physical Weight kgs Tower 12.8
Physical Weight lbs Tower 28.2
Physical Dimension mm Tower 130x382x195
Physical Dimension inch Tower 5.1x15.0x7.7
INDICATOR
LED LED
ALARM
Alarm Battery Backup Slow beeping sound (about 0.47 Hz)
Alarm Battery Low Rapid beeping sound (about 1.824Hz)
Alarm Overload Continue beeping sound
ENVIRONMENT
Environment Ambient 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg c
Environment Audible <40dBA (1 meter from surface)